Take off the grey grill. Unscrew the four screws located on
the perimeter of the device and then remove the cover from the
base.
Press the base horizontally against a wall, with the inlet and
exit point of water being below. attach with four screws.
Do not remove filter from inlet.
Connect the Atmor to the electricity cable with the aid of clamps,
designed to connect the zero line, the phase and the grounding
and lock the electric cable with the catch designed for these
purposes. It is essential to ground the device in accordance with
the electricity panel.
Turn on the device and check that it is operating effectively.
Reconnect the cover to the base with the four screws.
Make sure there is a decrease relay in the electricity panel.
Make sure there is a pressure unloading valve in your home water
system.